Common problems in operation and maintenance of Air Compressors:


38.Several air compressors use the same cooling water to cool down. Why is there difference in exhaust temperature?


        (1) the cooling effect of the cooler is different, such as scaling inside the cooler.

        (2) the load condition of the machine. If the difference of pressure settings between the two machines will affect the exhaust temperature.

        (3) Machine water pipe connection mode, in order to adapt to different working conditions, machine water pipe connection mode can be adjusted through the valve, or in series or in parallel.