Treatment method for long term shutdown of screw air compressor.
- Oct 18, 2018 -

Common problems in operation and maintenance of air compressors


7.Treatment method for long term shutdown of screw air compressor.


(1) shutdown for more than 3 weeks:

    1) clean the condensate in the oil cooler and after cooler.

    2) if there is any fault, it should be excluded first for future use.

    3) drain the condensate of the oil drum, the oil cooler and the rear cooler.

 

(2) shutdown for more than 2 months (except for the above procedure, the following should be done):

    1) close all openings to prevent moisture from entering.

    2) wrap the safety valve and the control panel with oil paper to prevent rust.

    3) Change the lubricating oil before stopping use and run for 30 minutes. After two days, remove the condensate water from the oil and gas barrel and cooler.

    4) drain all the cooling water.