What is the normal stopping procedure of screw air compressor?
- Oct 18, 2018 -

Common problems in operation and maintenance of air compressors


5.What is the normal stopping procedure of screw air compressor?


(1) the air compressor control switch is switched to the single control position.

(2) press the uninstall button and run at least 20 to 30s.

(3) press the "stop" button, the "run" signal lights out, and the motor stops. At present, most units simplify the stopping steps as follows: just press the stop button, the intake valve automatically closes, and then the relief valve unloads 20 seconds later, the unit automatically stops.

(4) open the drain valve and drain the condensate in the water separator.

(5) drain the cooling water from the cooler.

(6) close the exit door.