Common problems in operation and maintenance of Air Compressors:



33.Whether the noise housing of screw air compressor should be opened in operation?


Sound insulation cover not only eliminates noise in the operation of air compressor, but also is more conducive to ventilation and heat dissipation because of its special structure.

The sound shield is closed when the air compressor is running, and the air inlet of the cooling fan can enter through the air outlet reserved at the lower part of the sound shield.

These vents can effectively reduce the temperature of the corresponding position and improve the operation stability of the motor against the main engine, motor, oil and gas barrel of the air compressor. Therefore, the noise shield should not be opened during operation.